Description
SCHNEIDER ELECTRICRE22R1AMR
ON-DELAY TIMING
RELAY 1C/O 24-240V AC/DC
range of product
Zelio Time
product or component type
Modular timing relay
discrete output type
Relay
device short name
RE22
nominal output current
8 A
Complementary
contacts type and composition
1 C/O timed contact, cadmium free
time delay type
A
Aw
time delay range
0.05...1 s
0.3...3 s
1...10 s
10...100 s
3...30 h
3...30 min
3...30 s
30...300 h
30...300 min
30...300 s
control type
Rotary knob
Diagnostic button
[Us] rated supply voltage
24...240 V AC/DC at 50/60 Hz
input voltage
<= 2.4 V
voltage range
0.85...1.1 Us
supply frequency
50...60 Hz (+/- 5 %)
connections - terminals
Screw terminals : 1 x 0.5...1 x 3.3 mm², AWG 20...AWG 12 solid cable without cable end
Screw terminals : 2 x 0.5...2 x 2.5 mm², AWG 20...AWG 14 solid cable without cable end
Screw terminals : 1 x 0.2...1 x 2.5 mm², AWG 24...AWG 14 flexible cable with cable end
Screw terminals : 2 x 0.2...2 x 1.5 mm², AWG 24...AWG 16 flexible cable with cable end
tightening torque
0.6...1 N.m conforming to IEC 60947-1
housing material
Self-extinguishing
repeat accuracy
+/- 0.5 % conforming to IEC 61812-1
temperature drift
+/- 0.05 %/°C
voltage drift
+/- 0.2 %/V
setting accuracy of time delay
+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
minimum pulse duration
100 ms (with load in parallel)
30 ms
insulation resistance
100 MOhm at 500 V DC conforming to IEC 60664-1
reset time
120 ms (on de-energisation)
immunity to microbreaks
<= 10 ms
power consumption in VA
3 VA at 240 V AC
power consumption in W
1.5 W at 240 V DC
switching capacity in VA
2000 VA
minimum switching current
10 mA 5 V DC
maximum switching current
8 A
maximum switching voltage
250 V AC
electrical durability
100000 cycles for 8 A at 250 V AC-1
100000 cycles for 2 A at 24 V DC-1
mechanical durability
10000000 cycles
[Uimp] rated impulse withstand voltage
5 kV for 1.2...50 µs conforming to IEC 60664-1
delay response
< 100 ms
creepage distance
4 kV/3 conforming to IEC 60664-1
overvoltage category
III conforming to IEC 60664-1
safety reliability data
MTTFd = 308.2 years
B10d = 280000
mounting position
Any position
mounting support
35 mm DIN rail conforming to EN/IEC 60715
status LED
Green LED backlight (steady) for dial pointer indication
Yellow LED (steady) for output relay energised
Yellow LED (fast flashing) for timing in progress and output relay de-energised
Yellow LED (slow flashing) for timing in progress and output relay energised
width
22.5 mm
product weight
0.1 kg
time delay type
A, Aw
contacts type and composition
1 C/O
functionality
On-delay timing
Environment
dielectric strength
2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
standards
IEC 61812-1
UL 508
directives
2004/108/EC - electromagnetic compatibility
2006/95/EC - low voltage directive
product certifications
CCC
CE
CSA
GL
UL
RCM
EAC
China RoHS
ambient air temperature for operation
-20...60 °C
ambient air temperature for storage
-40...70 °C
IP degree of protection
IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front face) conforming to IEC 60529
pollution degree
3 conforming to IEC 60664-1
vibration resistance
20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6
shock resistance
15 gn (not operating) (duration = 11 ms) conforming to IEC 60068-2-27
5 gn (in operation) (duration = 11 ms) conforming to IEC 60068-2-27
relative humidity
95 % at 25...55 °C
electromagnetic compatibility
Fast transients immunity test (test level: 1 kV, level 3 - capacitive connecting clip) conforming to IEC 61000-4-4
Surge immunity test (test level: 1 kV, level 3 - differential mode) conforming to IEC 61000-4-5
Surge immunity test (test level: 2 kV, level 3 - common mode) conforming to IEC 61000-4-5
Electrostatic discharge (test level: 6 kV, level 3 - contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge (test level: 8 kV, level 3 - air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test (test level: 10 V/m, level 3 - 80 MHz...1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances (test level: 10 V, level 3 - 0.15...80 MHz) conforming to IEC 61000-4-6
Fast transient bursts (test level: 2 kV, level 3 - direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops (test level: 30 % - 500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops (test level: 100 % - 20 ms) conforming to IEC 61000-4-11